SetHomePage | AddFavorite | Sales Network  
Home About Us News Products Product manual download Sales Network Contact Us
Products  
Universal electronic controller
Industry of special instruments
The execution controller
Time relay
Count and speed measuring instrument
Overload circuit breaker
Integrated control box
Ground integrated control box
Programmable linear voltage regulator
Screen type programmable linear regulator
Thermocouple
thermal resistance
Instrument type table
Contact Us  
Address:Zhejiang,Yuyao,DongzhaoStreet,103
Phone:0574-62704891/627013406
Fax:0574-62721909
E-mail:gongbao@mail.nbptt.zj.cn
 
The execution controller Current Location:Home > Products > The execution controller

FJQ-03 three-phase thyristor zero trigger additional device

Add Date:2012-5-9 13:42:13 | Visits:

Product brief introduction: FJQ-03 three-phase thyristor zero trigger additional device and XMT - -75- XMT - -75, - P, XMT - -75- H, XTT - -75- XMT-15 -, XMT -, -25- output DC step current signals to a main control instrument is connected, can be conveniently in order to zero trigger mode to drive the three road SCR, the three-phase load of power regulation. With matching flexibility, reliable use, adapted to the various connection modes of load characteristics, can be widely used for various electric resistance furnace with high precision temperature automatic control system.

One, the main technical parameters:

The 1 input: master the instrument 0-15mA DC current step signal ( that is the master instrument driver solid state relay output )

The 2 trigger output allows circulation trigger current:3 × 1A

The 3 trigger output maximum voltage: DC700V

4zero trigger cycle time: master controlling meter decided by

5dimensions: ( W x H x D) : 100x 65x 120

The 6installation hole size: 92x 85

7installation methods: built-in type screen

Two, wiring, installation, use guide:

The 1Wiring Regulations see photos.

2 according to the selection of main control instrument and load conditions selected a wiring diagram, strictly according to the selected terminal wiring diagram.

3of the additional device for "1","2" input should access the master controlling meter0-15mA DC step drive signal output end of positive and negative polarity, may not be reversed.

The 4input terminal has normal signal, additional device indicator light, and the output terminal is connected, otherwise the circuit breaker.

5to the resistive load half power heating, the terminal can be respectively connected by"5" for"6","10" by grafting for"11","14" by grafting for"7" ( now flowing through the load is half wave alternating current). This method can greatly extend the life of furnace heating wire heating rate decreased, but the.

6 if the controllable silicon or a line breaker, or mistaking a unidirectional controlled silicon as the bidirectional thyristor is used, will burn additional device external R1insurance resistance (1/4W 1.5 Ω), this time should be replaced and troubleshooting before reuse.

7 may not drive the induction furnace, transformers and inductive load.


Prev:FJQ-3phase shift or zero thyristor trigger additional device
Next:Integral type power voltage regulator
Links
           
Copyright: Yuyao temperature instrument factory limited liability company Zhejiang ICP preparation08009260